dd
dd
 

Open circuit maximum capacities

tph

Closed side setting - mm

3 mm

6 mm

10 mm

13 mm

16 mm

19 mm

25 mm

32 mm

38 mm

Short

30

60

75

100

120

130

145

160

180

Metric

27

54

68

91

109

118

132

145

164

 

Product gradations – percent passing

Product size

Closed side setting – mm

(Note: Figures for 6mm – 19mm closed side settings are for closed circuit application and the rest are for the open circuit application)

 

6 mm

10 mm

13 mm

19 mm

25 mm

31mm

38 mm

100 mm

 

 

 

 

 

 

 

75 mm

 

 

 

 

 

 

100

64 mm

 

 

 

 

 

100

90

50 mm

 

 

 

 

100

90

80

38 mm

 

 

 

100

90

80

60

32 mm

 

 

 

90

80

60

46

25 mm

 

 

100

85

60

43

30

19 mm

 

100

85

60

40

29

20

13 mm

100

85

60

35

22

17

14

10 mm

85

60

40

22

16

13

11

6 mm

60

35

22

14

11

9

7

5 mm

40

22

16

11

8

7

5

3 mm

24

15

12

8

6

5

3

2 mm

16

11

8

6

4

3

2

 

Note:

 

The values are for the average feed material with WI = 12 to 14

 

The values in the above tables will vary with the method of feeding, feed distribution, feed segregation, crushing cavity, bulk density, fines in the feed, moisture content, fracture characteristics, speed, etc.

 

 

 

 

 

 

 

  

e
Innovative mobile and semi-mobile crushing, screening and material-handing solutions.....

22